Naturwissenschaften
Dauerhafte URI für die Sektionhttps://epub.uni-luebeck.de/handle/zhb_hl/3
Listen
Auflistung Naturwissenschaften nach Instituten/Kliniken "Institut für Biomedizinische Optik"
Gerade angezeigt 1 - 20 von 21
- Treffer pro Seite
- Sortieroptionen
Item 850 nm Fourier domain mode-locked laser for ophthalmic optical coherence tomography imaging(2025) Klufts, MarieNon-invasive imaging techniques have become essential in medical diagnostics over the past few decades. Among these, Optical Coherence Tomography (OCT) offers micrometer resolution with millimeter-scale depth penetration, making it particularly valuable in ophthalmology. OCT captures backscattered light to generate 3D volumes. For eye imaging, wavelengths around 850 nm are ideal due to minimal absorption by the vitreous and high scattering in the upper retinal layers. Imaging speed is also critical, as faster speeds reduce motion artifacts. Swept-source OCT, using wavelength-tunable lasers, enables high-speed imaging. Fourier Domain Mode-Locked (FDML) lasers providing megahertz-level scan rates are ideal for this purpose. This thesis explores the development and application of FDML lasers for ophthalmic imaging. Unlike other tunable lasers, FDML lasers have a unique design that stores a full sweep in their fiber cavity for hundreds of round trips, avoiding rebuilding of lasing from spontaneous emission after tuning to new wavelengths offering high phase stability and long coherence length necessary for high quality OCT images. A new megahertz FDML laser at 850 nm would merge the unique advantages of this wavelength with the proven benefits of FDML lasers allowing for a low latency, dynamic view of the retina, opening new doors for real-time diagnostics. The first part delves into the challenges of developing an FDML laser around 850 nm, addressing issues like polarization mode dispersion, chromatic dispersion, and low gain/loss ratios. These factors contribute to the complexity of managing short wavelength OCT lasers, which explain their scarcity to date. The second part presents in-vivo ophthalmic OCT imaging results, with comparisons to other imaging techniques. The newly designed FDML laser demonstrates strong performance for OCT imaging, achieving an axial resolution below 10 µm, sensitivity above 84 dB, and a ranging depth of 1.4 cm. Also, its high phase stability, with a time jitter of 25 ps over 1,000 sweeps, makes it suitable for phaseresolved techniques. Retinal images were captured at 414,000 axial scans per second using a master-slave based calibration technique, at 828 kHz with bidirectional sweeping, and at 1.7 MHz using optical buffering with a single-k-calibration technique. While increased scattering at 850 nm limits choroidal imaging, most retinal layers of interest are clearly visible. This FDML laser highlights the advantages of short-wavelength, high-speed imaging and paves the way for new applications.Item Advances in femtosecond laser refractive eye surgery(2025) Freidank, SebastianThe advent of reliable short-pulsed lasers in the 1980s and 1990s made it possible to perform refractive laser surgery that offers correction without glasses. In laser-assisted in situ keratomileusis (LASIK), argon fluoride excimer laser ablation at 193 nm wavelength was employed to ablate central corneal stroma that had been exposed by cutting a flap using a mechanical microkeratome. Later, the mechanical keratome was replaced by a femtosecond (fs) laser that can produce a corneal dissection through applying a grid of near-IR laser pulses at 1030 nm with small energy at high repetition rate. This way, flaps with flat bed and side cut can be produced that enable precise repositioning of the flap after surgery. It enables to perform wave front-guided ablation for correction of higher-order aberrations besides myopia or hyperopia. In the 2010s, small incision lenticule extraction (SmILE) was introduced, in which a lenticule is dissected out of the central stroma using only fs laser pulses and removed through a small side cut. This technique requires only one laser and optical delivery system and involves less dissection of corneal nerves and biomechanical weakening of the cornea than LASIK. The thesis analyses the mechanisms of corneal dissection and explores novel dissection concepts for improving precision, efficacy and gentleness of refractive surgery both in LASIK and SmILE. Dissection relies on a sequence of laser-induced plasma formation, shock wave emission, and cavitation bubble dynamics. Pulse repetition rate, energy and spot separation influence the interaction of events from subsequent laser pulses and, thus, the cutting dynamics. The fundamentals of plasma formation and its dependence on laser pulse duration, wavelength, focusing angle and focus shape are described using generic equations for photo- and avalanche ionization, thermal ionization, and recombination. Laser-induced bubble formation and its interplay with shock wave emission is described using an extended Gilmore model of cavitation bubble dynamics. This analysis and previous experiments show that UVA sub-nanosecond laser pulses with stable temporal shape and a wavelength around 350 nm offer the potential of creating more precise cuts with more compact devices than conventional near-IR fs laser systems. Furthermore, the introduction of a helical phase plate can transform the Gaussian laser beam with elongated focus into a vortex beam with a ring shaped focus of similar length. Such focus shaping promises to improve the dissection efficacy in direction parallel to the corneal surface, which should reduce mechanical side effects and increase precision. The dynamics of corneal dissection by 330 fs, 1030 nm laser pulses was investigated using stroboscopic photography with sub-micrometer spatial resolution, high-speed photography with up to 50 million frames/s and videography at 1 kHz. The cavitation bubble size was determined from stroboscopic photographs through digital image evaluation. The morphology of the cuts was investigated histologically, and the quality of the cuts evaluated through scanning electron microscopy. It turned out that the plasma extends through several corneal lamellae and its rapid expansion leads to irregularly shaped lobular cavitation bubbles. Lobes from neighboring bubbles do not always meet, which leads to tissue bridges hindering flap lifting and lenticule extraction. The cutting process is largely an addition of individual disruption/cleavage effects, which depend mainly on pulse energy and spot separation. However, it has also a dynamic component resembling crack propagation during fracture in solids, which implicates a dependence on pulse repetition rate. The use of a vortex beam was explored for IR and UV wavelengths and found to improve dissection efficiency and quality. Scanning electron microscopy showed that the cuts are smoother than with a Gaussian beam. The force distribution during the plasma expansion from a ring focus facilitates tissue cleavage in the cutting direction parallel to the corneal surface and minimizes tissue bridges. Therefore, the volumetric energy density in the focal volume required for dissection is smaller with a vortex beam than with a Gaussian beam, which reduces plasma pressure and mechanical side effects. The smaller plasma energy density results also in less gas generation through free-electron-mediated molecular disintegration. This is advantageous because long-lived gas bubbles impair pupil tracking during clinical procedures and distort the corneal morphology during dissection of the upper lenticule cut in SmILE. Altogether, dissection using a vortex beam is more precise and gentler than with a Gaussian beam. Experiments with fs pulses at 343 nm wavelength and sub-ns pulses at 355 nm showed that the precision of corneal dissection could be further improved by reducing the laser wavelength. However, although the damage potential of the investigated UVA wavelengths lies four orders of magnitude below the peak value around 260 nm and although no corneal damage has been observed in previous animal experiments, the radiant exposure required for flap cutting lies above the permissible dose. The pulse duration dependence of laser pulse energy required for dissection with easy flap lifting was investigated for IR pulses between 480 fs and 8 ps duration and UV pulses between 1 ps and 400 ps duration. A strong pulse duration dependence is found even for the absorbed laser energy needed for flap cutting, which indicates that the efficiency of the cutting process drops. For durations L > 10 ps, stress and inertial confinement of energy deposition decrease, which reduces the plasma peak pressure and delays or even inhibits the formation of a shock front. For L < 3 ps, the reduced cutting energy is related to an increase of plasma energy density with decreasing pulse duration. These findings confirm the high suitability of pulse durations in the lower fs range down to about 150 fs, which are used in state-of the art clinical laser systems. The improvement of dissection through use of a vortex beam instead of a Gaussian beam is the finding of this thesis with greatest clinical relevance and potential for LASIK and SmILE. It has already been demonstrated that a helical phase plate can be easily implemented into the beam delivery system of existing clinical devices and is compatible with focus scanning. The next step is the conduction of a clinical study.Item Automated selective retina therapy(2024) Seifert, EricItem Dynamische mikroskopische Optische Kohärenztomografie(2024-11-07) Münter, MichaelDie vorliegende Arbeit beschreibt ein Verfahren zur kontrastreichen Bildgebung von zellulären und subzellulären Strukturen mittels mikroskopischer Optischer Kohärenztomografie (OCT). Die auch als dynamischer OCT Kontrast bezeichnete Methode basiert auf der Detektion von Bewegungen zellulärer und subzellulärer Strukturen und einer anschließenden Auswertung. Im Theorieteil werden die biologischen und physikalischen Grundlagen als auch die OCT beschrieben. Die physikalischen und mathematischen Grundlagen der für den dynamischen OCT Kontrast wichtigen Schritte werden in den darauffolgenden Kapitel genauer untersucht. Zuerst werden Ergebnisse mit einem mikroskopischen OCT Aufbau bei einer A Scan Rate von 248 kHz vorgestellt. Hierbei konnte anhand von Volumen und B Scan Aufnahmen von frischen ex vivo Gewebeproben eine Bildgebung mit dynamischen OCT Kontrast mittels scannender Spectral-Domain OCT demonstriert werden. Zur Evaluation der Ergebnisse wurden diese mit einem Full Field Time Domain OCT Aufbau verglichen. Die Abhängigkeit der axialen Auflösung durch Anpassung der Hann Fensterung bei der Rekonstruktion auf den dynamischen OCT Kontrast wurde untersucht. Zudem erfolgt eine Betrachtung des Kontrast Rausch Verhältnisses in Abhängigkeit zur Aufnahmezeit. Es konnte gezeigt werden, dass bereits eine Aufnahmezeit von 100 ms ausreichend ist, um zelluläre und subzelluläre Strukturen mittels dynamischen OCT Kontrast zu visualisieren. In Zeitserien mit dynamischen OCT Kontrast konnten Immunzellen in der Bewegung beobachtet werden, die mit herkömmlicher OCT-Bildgebung nicht hätten visualisiert werden können. Um die Bildgebungsgeschwindigkeit zu erhöhen, wurde eine Zeilenkamera mit einer Auslesegeschwindigkeit von 600 kHz für den mOCT Aufbau eingesetzt. Hierfür wurde eine angepasste OCT Software zur Online-Darstellung von B Scans und eine Auswertungssoftware geschrieben. Anhand einer technischen Charakterisierung wurde die Zeilenkamera mit 248 kHz Ausleserate mit der 600 kHz Zeilenkamera verglichen. Die Vorteile einer schnelleren Bildgebung wurden durch die Darstellung dynamischer 4 dimensionaler Transportvorgänge in ex vivo Trachea gezeigt als auch an dynamischen OCT Aufnahmen von unfixierten ex vivo Proben. Dynamische OCT erweitert die OCT durch die bisher nicht erreichte kontrastreiche Darstellung von Zellen und subzellulären Strukturen und stellt damit eine wichtige Applikation für hochauflösende OCT dar.Item Erforschung der Kohärenzeigenschaften von FDML-Lasern durch Schwebungsmessungen(2022) Grill, ChristinItem Lineare OCT Verfahren(2016) Koch, Klaus PeterItem Item Mikroskopisch optische Kohärenztomographie für die Darstellung von Mukustransport(2019) Schulz-Hildebrandt, HinnerkItem Multiphotonenmikroskopie mit einem aktiv modulierten Faserlaser(2019) Eibl, MatthiasItem Quantitative measurement of cellular dynamics using spectral domain optical coherence phase microscopy(2013) Mohammed Abdul, Rehman AnsariItem Item Reaktionen von Zellen des retinalen Pigmentepithels auf transiente Hyperthermie(2019) Kern, KatharinaItem Robotische, endoskopische und dynamische Megahertz-Optische Kohärenztomographie und deren Anwendungen in Klinik und Forschung(2025) Göb, MaditaDie Optische Kohärenztomographie (OCT, engl. optical coherence tomography) hat sich als leistungsstarke Technik zur dreidimensionalen Visualisierung von Gewebestrukturen etabliert. Forschungsergebnisse zeigen das enorme Potenzial dieser Technologie zwischen gesundem und pathologischem Gewebe zu unterscheiden. Im Gegensatz zur Biopsie ist OCT nicht-invasiv und liefert sofortige diagnostische Ergebnisse. Dennoch stoßen handelsübliche OCT-Systeme aufgrund langsamer Scangeschwindigkeiten und kleiner Bildfelder im klinischen Alltag an ihre Grenzen. Die MHz-OCT, eine Weiterentwicklung mit Linienraten im Megahertz-Bereich, überwindet diese Einschränkungen und ermöglicht ultraschnelle 3D-Bildgebung in Echtzeit. Um die hohe Geschwindigkeit der MHz-OCT gezielt nutzbar zu machen, wurden im Rahmen dieser Arbeit drei neuartige Systeme entwickelt und ihre Anwendungen in spezifischen medizinischen und wissenschaftlichen Bereichen erforscht: 1. Robotische MHz-OCT: Eine robotergestützte Plattform wurde für die automatisierte Bildgebung großer Bereiche entwickelt. Mit zwei verschiedenen Robotersystemen wird eine präzise Abtastung ganzer Hautareale in vivo demonstriert sowie die Eignung als automatisiertes Hochdurchsatz-Messgerät für innovative ex vivo Forschungsansätze in der Dermatologie. 2. Endoskopische MHz-OCT: Ein 4D-Echtzeit-OCT-Endoskop wurde konzipiert, das die Lumen-Topografie abbildet und mikroskopische Einblicke in die Gewebemorphologie liefert. Kolorektale Bildgebungsexperimente an Körperspendern zeigen die mögliche Anwendung zur Früherkennung gastrointestinaler Läsionen und der Beurteilung tiefer Gewebeschichten. 3. Dynamische MHz-OCT: Zur Analyse physiologischer und metabolischer Prozesse wurde die MHz-OCT um ein Verfahren zur dynamischen Bildgebung erweitert. Diese Technologie bietet durch zusätzlichen funktionellen Kontrast detaillierte Einblicke in zelluläre Strukturen, ähnlich der Histologie, und deren Funktion. Die Methodik wird an ex vivo Gewebe demonstriert. Diese Ansätze zeigen das Potenzial der MHz-OCT, diagnostische Verfahren nicht nur zu ergänzen, sondern auch neue Anwendungsfelder in der medizinischen Bildgebung zu erschließen. Die vorliegende Arbeit beschreibt die Entwicklung, Validierung und Anwendung dieser Methoden sowie deren Beitrag zur Integration der MHz-OCT in die klinische Praxis.Item Two-photon microscopy and UV laser nanosurgery of murine small intestine in vivo(2014) Orzekowsky-Schroeder, Regina BernadetteItem Item Verbesserung und Anwendung der ultraschnellen optischen Kohärenztomographie am menschlichen Auge(2018) Kolb, Jan Philip